VIASURE Respiratory Monoplex: Respiratory Infections RT PCR Kit provides maximum flexibility and compatibility with leading open system thermal cyclers.
VIASURE Respiratory Monoplex: Respiratory Infections
VIASURE Bocavirus Real Time PCR Detection Kit is designed for specific identification of human Bocavirus in respiratory samples from patients with signs and symptoms of respiratory infection.
This test is intended for use as an aid in the diagnosis of Bocavirus infection in combination with clinical and epidemiological risk factors.
DNA is extracted from specimens, multiplied using Real Time amplification and detected using specific primers and a fluorescent reporter dye probe for Bocavirus.
VIASURE Human Metapneumovirus Real Time PCR Detection Kit is designed for specific identification of human Metapneumovirus in respiratory samples from patients with signs and symptoms of respiratory infection.
This test is intended for use as an aid in the diagnosis of human Metapneumovirus in combination with clinical and epidemiological risk factors.
RNA is extracted from specimens, amplified using RT-PCR and detected using fluorescent reporter dye probes specific for human Metapneumovirus.
VIASURE Influenza A Real Time PCR Detection Kit is designed for specific identification and quantification of Influenza A in clinical samples from patients with signs and symptoms of respiratory infection.
This test is intended for use as an aid in the diagnosis of Influenza A in humans in combination with clinical and epidemiological risk factors.
RNA is extracted from specimens, amplified using RT‐amplification and detected using fluorescent reporter dye probes specific for Influenza A.
VIASURE Influenza H1N1 Real Time PCR Detection Kit is designed for specific identification and quantification of Influenza A (H1N1)2009 in clinical samples from patients with signs and symptoms of respiratory infection.
This test is intended for use as an aid in the diagnosis of Influenza A (H1N1)2009 in humans in combination with clinical and epidemiological risk factors.
RNA is extracted from specimens, amplified using RT‐amplification and detected using fluorescent reporter dye probes specific for Influenza A (H1N1)2009.
VIASURE Influenza B Real Time PCR Detection Kit is designed for specific identification and quantification of Influenza B in clinical samples from patients with signs and symptoms of respiratory infection.
This test is intended for use as an aid in the diagnosis of Influenza B in humans in combination with clinical and epidemiological risk factors.
RNA is extracted from specimens, amplified using RT‐amplification and detected using fluorescent reporter dye probes specific for Influenza B.
VIASURE Parainfluenza 1 Real Time PCR Detection Kit is designed for specific identification of Parainfluenza 1 in respiratory samples from patients with signs and symptoms of respiratory infection.
This test is intended for use as an aid in the diagnosis of Parainfluenza 1 in combination with clinical and epidemiological risk factors.
RNA is extracted from specimens, amplified using RT-PCR and detected using fluorescent reporter dye probes specific for Parainfluenza 1.
VIASURE Parainfluenza 2 Real Time PCR Detection Kit is designed for specific identification of Parainfluenza 2 in respiratory samples from patients with signs and symptoms of respiratory infection.
This test is intended for use as an aid in the diagnosis of Parainfluenza 2 in combination with clinical and epidemiological risk factors.
RNA is extracted from specimens, amplified using RT-PCR and detected using fluorescent reporter dye probes specific for Parainfluenza 2.
VIASURE Parainfluenza 3 Real Time PCR Detection Kit is designed for specific identification of Parainfluenza 3 in respiratory samples from patients with signs and symptoms of respiratory infection.
This test is intended for use as an aid in the diagnosis of Parainfluenza 3 in combination with clinical and epidemiological risk factors.
RNA is extracted from specimens, amplified using RT-PCR and detected using fluorescent reporter dye probes specific for Parainfluenza 3.
VIASURE Parainfluenza 4 Real Time PCR Detection Kit is designed for specific identification of Parainfluenza 4 in respiratory samples from patients with signs and symptoms of respiratory infection.
This test is intended for use as an aid in the diagnosis of Parainfluenza 4 in combination with clinical and epidemiological risk factors.
RNA is extracted from specimens, amplified using RT-PCR and detected using fluorescent reporter dye probes specific for Parainfluenza 4.
VIASURE RSV A Real Time PCR Detection Kit is designed for specific identification of Human Respiratory Syncytial Virus type A (RSV A) in respiratory samples from patients with signs and symptoms of respiratory infection.
This test is intended for use as an aid in the diagnosis of RSV A in combination with clinical and epidemiological risk factors.
RNA is extracted from specimens, amplified using RT-PCR and detected using fluorescent reporter dye probe specific for RSV A.
VIASURE RSV B Real Time PCR Detection Kit is designed for specific identification of Human Respiratory Syncytial Virus type B (RSV B) in respiratory samples from patients with signs and symptoms of respiratory infection.
This test is intended for use as an aid in the diagnosis of RSV B in combination with clinical and epidemiological risk factors.
RNA is extracted from specimens, amplified using RT-PCR and detected using fluorescent reporter dye probe specific for RSV B.
VIASURE Legionella pneumophila Real Time PCR Detection Kit is designed for specific identification of Legionella pneumophila in clinical samples from patients with signs and symptoms of legionellosis.
This test is intended for use as an aid in the diagnosis of Legionella pneumophila in humans in combination with clinical and epidemiological risk factors.
DNA is extracted from clinical specimens, multiplied using Real Time amplification and detected using specific primers and a fluorescent reporter dye probe for Legionella pneumophila.
VIASURE M. tuberculosis complex Real Time PCR Detection Kit is designed for specific detection of M. tuberculosis complex species in respiratory samples from patients with signs and symptoms of Tuberculosis infection.
This test is intended for use as an aid in the diagnosis of the Tuberculosis in combination with clinical and epidemiological risk factors.
DNA is extracted from specimens, multiplied using real time amplification and detected using fluorescent reporter dye probes specific for M. tuberculosis complex strains.
VIASURE Group A Streptococcus Real Time PCR Detection Kit is designed for the specific detection of DNA of the Streptococcus pyogenes (group A (beta-hemolytic) Streptococcus (Strep-A)) in pharyngeal and otic exudate swabs from patients with signs and symptoms of respiratory infection.
This test is intended to be used as an aid in the diagnosis of Streptococcus pyogenes infection in combination with clinical and epidemiological risk factors.
DNA is extracted from specimens, multiplied using Real Time amplification and detected using specific primers and a fluorescent reporter dye probe for Streptococcus pyogenes.
VIASURE Pneumocystis jirovecii Real Time PCR Detection Kit is designed for specific identification of Pneumocystis jirovecii in respiratory samples from patients with signs and symptoms of respiratory infection.
This test is intended for use as an aid in the diagnosis of Pneumocystis jirovecii in combination with clinical and epidemiological risk factors.
DNA is extracted from clinical specimens, multiplied using Real Time amplification and detected using specific primers and a fluorescent reporter dye probe for Pneumocystis jirovecii.